WELLINGTON ICU

About this simulator

Developed by Alex Psirides using an advanced AI model. Trained on public access datasets. See below for sources.

Echo suite v2.48TTE model v1.83.2TOE model v2.37Build date & time 24 November 2026, 07:36 NZDT

The selection screen follows the ICU Simulator mode-menu styling. Examinations load only when selected; leaving an examination pauses it without discarding its controls or accumulating hidden time.

Experimental TOE

The TOE model is procedural 3D anatomy, not a reconstruction from TOE patient volumes. Its cardiac timing and sinus ECG draw on existing TTE/ICU Simulator code. It includes five mid-oesophageal views, two transgastric views, acquisition practice and ECG-synchronised spectral Doppler. It is not clinically validated.

ASE/SCA comprehensive TEE examination · Basic examination · Toronto Virtual TEE

Reference recordings are linked externally and require internet access. No recorded TOE cine or Toronto assets are embedded. Both synthetic modules work offline after this HTML file is downloaded.

Toronto TEE: Standard Views (University Health Network, version 2.05). Reviewed for acquisition and anatomical orientation. Its normal views informed qualitative anatomy, orientation and acquisition refinements in TOE v2.2. No source assets are embedded.

Right atrial continuity (v2.48)

The right atrial wall and the atrial end of the tricuspid inlet now use shared moving curves. Previously the wall could buckle inward during tamponade while the inlet still ended at its uncollapsed position, leaving a gap where the blood mask cut the wall. The annular end remains supported as the atrial body moves. Inner and outer surfaces retain a wall margin through the tested cycle. A separate interatrial septal stroke had also left a protected low-signal track through septal tissue; it has been removed. The actual atrial shells still supply septal anatomy and structure labels. The v2.47 pericardial outline correction is retained. Haemodynamics, collapse timing and preset values are unchanged.

Effusion contour correction (v2.47)

A separate uniform bright ribbon previously outlined the sampled TTE pericardial contour. Its joins could appear as straight lines in the apparent fluid space. This duplicate overlay has been removed. The textured parietal tissue now meets the same outer fluid boundary directly, with no extra outline or gap. Fluid-space geometry, slider response and tamponade haemodynamics are retained. The TOE volumetric echo renderer is unchanged.

Structural pathologies (v2.46)

Six scenarios are shared by TTE and TOE. Flail anterior mitral leaflet is separate from partial papillary muscle rupture. The latter retains a wall-side stump, and a mobile head connected to the leaflet by chordae. HCM has basal septal thickening and systolic anterior mitral motion with a separate subvalvar pressure loss; the aortic valve is not made stenotic. ASD and VSD are openings in the shared septal anatomy. Shunt flow follows instantaneous atrial or ventricular pressure differences and transfers blood within the closed circulation. The congenital perimembranous VSD is separate from an illustrative post-infarction apical septal rupture with apical dysfunction. Lesions appear only in planes that intersect them.

Public cine references from Prague ICU: mitral regurgitation, videos 9–10 and 16 (papillary rupture and anterior flail); HCM, videos 5 and 11–12 (SAM/LVOT obstruction); ASD, videos 5–8; VSD, congenital TTE/TOE examples and post-infarction examples. Guideline cross-checks: ASE HCM imaging recommendations (2022); ASE/SCAI ASD/PFO assessment (2015); AHA mechanical complications of myocardial infarction statement (2021). Cine labels and temporal visual cues inform bounded procedural morphology. No loop measurements, tissue strain, defect size, gradient or disease severity have been fitted. Chamber controls are reference targets, not echo measurements. No clinical validation is claimed.

Scenario parity (v2.45)

TTE and TOE share the same 28 scenario names, category headings and order. Visibility remains view-dependent. The left atrial appendage is outside the anatomy represented by the four current TTE views: selecting its thrombus preset displays that limitation and does not create a substitute mass in the LA body. TOE retains its dedicated appendage-thrombus geometry. The existing 27 TTE physiology settings are unchanged.

Appendage imaging reference: ASE Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism (2016), LA/LAA thrombus section. Menu parity does not imply equal diagnostic visibility between TTE and TOE.

Tissue appearance and material motion (v2.44)

TTE uses a softer display response and lower repeated interface amplification to retain mid-grey tissue detail. Its persistent scatterer field has a slightly finer beam response, bounded material heterogeneity and reduced independent phase decorrelation. PLAX left-atrial deformation follows the existing atrial reservoir/conduit model and shared annular excursion. Atrial and aortic-wall texture is transported on their moving surfaces, rather than rescaled inside a bounding box. The PLAX atrial mural-thrombus anchor and mitral regurgitant target use the same moving atrial geometry.

TOE myocardial material coordinates follow the current/reference ventricular sections, including the prior annular loft and regional shortening. Apical caps and tissue outside the ventricular section retain spatial variation. Lower, texture-modulated wall-interface highlights avoid a continuous bright rim. These are bounded synthetic rendering refinements, not a new fit to source loops or new clinical validation. Valve surfaces, Doppler origins and shared haemodynamic equations remain intact. Existing references and full release history are retained.

TOE anatomical continuity and thin leaflets (v2.43)

The RV inlet now shares a moving annular ellipse on both sides of the tricuspid valve, with a smooth transition to the ventricular body. A more curved LV profile follows the existing material and regional-motion coordinates. Rendering-profile normalisation preserves the preceding integrated LV/RV lumen cross-sections; it does not recalibrate the synthetic model to patient measurements. The pericardial envelope uses a patient-specific end-diastolic reference and smooth axial/apical joins so it does not contract as a second myocardial wall. The existing tamponade pressure and chamber-collapse equations remain unchanged.

Thin MV and TV echoes use finer, local Gaussian elevation sampling of their existing 3D surfaces, including faint contributions from the finite slice thickness. Central-plane labels, leaflet geometry, thrombus/vegetation attachment and Doppler origins are retained. This is an acoustic sampling refinement, not a line drawn to connect a mass. The anatomical reference framework remains the ASE/SCA comprehensive TOE guideline and the acknowledged University of Toronto standard-view atlas. The refinements are synthetic engineering changes and do not constitute clinical validation.

Basal contours and boundary rendering (v2.41)

TTE now starts in a 2 × 2 layout at all viewport widths. The layout button still selects 4 × 1, 2 × 2 or 1 × 4, and menu returns preserve the current choice. Visible basal PLAX contour joins share a tangent while retaining their existing knots. The mitral inflow connector has curved sides that pass through its moving hinges, and the posterior pericardial surface follows the same outer LV contour. The source geometry profiles and physiological equations remain intact; these are bounded changes to synthetic display geometry.

The anatomical review uses the previously acknowledged Echocardiographer.org PLAX guide and normal loop and the BSE minimum dataset guideline. Reference review informs orientation and visible anatomical continuity; it does not clinically validate this model. TTE myocardial contrast is reduced to retain more mid-grey detail. TOE uses additional in-plane corner classification only at tissue–blood boundaries, with unchanged central labels and protected valves, masses and pericardial fluid. Spatial resolution, finite-beam sampling, phase counts and Doppler equations are retained. Native-image comparisons and complete-cycle geometry checks are engineering tests, not clinical validation.

Release audit and rendering cleanup (v2.40)

The pre-test release audit removed unreferenced legacy renderers, unused texture preparation and obsolete research styles. Active anatomy, physiological equations, source-derived profiles, scattering, finite-beam sampling and image resolution remain unchanged. Physiological arcs update when their values change, rather than being repainted with every image. The TOE display buffer is reused and identical TTE mask-canvas creation uses one helper.

The rendering pipeline now drains its queue after a fallback or painting error and falls back safely if worker message submission fails. A current TOE rendering failure pauses playback, displays a retry message in the existing status area and rejects pending completion requests. Stale errors cannot overwrite a newer display request. TTE image capture now applies the current B-mode gain and contrast, with an export-only brightness/contrast fallback where native canvas filters are unavailable. The embedded TTE layout uses the visible shell width at startup. M-mode captures use current release metadata, and Escape restores the correct enlargement hint. Shared ECG and haemodynamic code remains independently embedded where required by the separate TTE and TOE documents. Engineering regression checks compare the active images and Doppler data against v2.39; they do not constitute clinical validation.

Exact-result rendering caches (v2.39)

This performance update caches repeated coordinate transformations and unchanged masks. TOE retains a maximum of four ray-to-beam lookup maps, with double-precision interpolation fractions. TTE retains the immutable sector-mask pixels, avoiding a repeated canvas readback and allocation. Its beam-grid calculations remain unchanged. Private Doppler route calculations use weak references to unchanged sampled models. An unchanged TOE 3D guide is copied at its original size only when its committed frame, camera and canvas dimensions match. The caches add a bounded amount of memory in exchange for less repeated work.

Image resolution, scatterer density, tissue reflectivity, finite-beam samples, image-phase counts, spectral sampling, physiological equations and clinical scenarios are unchanged. Pixel and spectral comparisons against v2.38 form the regression criteria for this release. These engineering checks do not constitute clinical validation.

Wall-interface contrast and Doppler preparation (v2.38)

Ventricular tissue has a bounded angle-dependent reflective contribution near its existing endocardial surface, alongside diffuse myocardial scattering. TTE uses near-endocardial scatterer weights carried by the established moving material mesh. TOE evaluates a thin response inside the existing myocardial volume before its finite-beam receive processing. Neither method draws a new chamber outline or changes lumen geometry, physiological targets, valve attachments or pathological masses. The response remains an uncalibrated engineering approximation, reviewed qualitatively against closed/open phases in the previously acknowledged Toronto reference cines.

The rendering choices draw on the BSE adult TTE minimum dataset (gain and endocardial-border optimisation) and the ASE cardiac ultrasound artifacts guideline (angle-dependent tissue visibility). These references inform design, rather than validate synthetic images or calibrate tissue reflectivity.

TOE Doppler cycle and profile preparation now runs in the existing background worker, with one cached 192-phase patient model and four spectral profiles. The displayed waveform is delivered with its matching B-mode frame and committed ECG clock. The original equations, spectral sampling and scale selection are retained. Rapid probe, gate or patient changes invalidate older responses, and the existing worker-unavailable fallback remains available. No controls or examination modes were added.

Ultrasound appearance and background rendering (v2.37)

Finer myocardial correlation and tissue-dependent scattering are evaluated in material coordinates, so texture follows contraction rather than sliding over the image. TTE uses denser, power-normalised scatterers and a narrower bounded beam kernel. TOE uses smaller coherent myocardial cells, subtle solid wall-connected ridges and asymmetric papillary profiles. RV detail is coarser than LV detail, and the smooth basal outflow region is preserved. These are engineering geometry and image-formation rules, not newly fitted patient anatomy.

A bounded path response reduces echoes through tissue and permits modest enhancement beyond fluid. Pericardial fluid stays dark, hydraulic geometry and labels are unchanged by this display pass, and calcific shadowing retains priority. The response is not calibrated to a scanner, MHz or dB/cm. References: ASE cardiac ultrasound artifacts guideline (2026); ASE right-heart guideline (2025); and the previously acknowledged clinical cines.

TOE B-mode image computation runs in one worker created from scripts embedded in this HTML. A single pending job replaces older queued jobs, and revision checks reject results from superseded probe/patient settings. The image, guide and displayed ECG/spectral clock commit together. Cached frames use the same model and renderer. A fallback remains available where workers are unavailable. This supports offline operation without a separate worker file. Browser, stale-result, phase synchronisation, image, anatomy, scenario and performance tests describe engineering behaviour and do not establish clinical validation.

Motion and rendering refinement (v2.36)

Leaflet body curvature and chordal slack respond to the existing pressure/opening state. Hinges, normal coaptation endpoints and hydraulic apertures retain their shared geometry. TOE vegetations have a fixed attachment and a flexible distal centreline used by the sampled volume, guide mesh and material texture. Continuous depth sweeps use a stable horizontal reference through the deep transgastric transition, avoiding the former orientation singularity at extreme flexion and rotation. The standard view endpoints are retained.

Qualitative motion review used the previously acknowledged Prague ICU mitral stenosis, mitral regurgitation, tricuspid regurgitation, aortic regurgitation and endocarditis cines, alongside the Toronto standard-view references. No patient-specific fitting, new training dataset or clinical validation is claimed for these bounded display rules. The existing RA/RV collapse phases were reviewed against the ASE pericardial imaging recommendations; removing the mandatory RA indentation allows raised right-sided filling pressure to suppress this illustrative sign. The reduced physiology and its pressure thresholds remain engineering assumptions.

Rendering retains the same resolution, central-plane anatomical labels, finite beam width and receive response. Exact optimisations reuse repeated LVOT point tests, skip geometry outside its declared domain, retain ordered spatial candidates for the pulmonary outflow, and unroll the material-field interpolation. Geometry and material caches remain bounded and patient/phase-specific. The release was checked with paired images before motion changes, continuous probe sweeps, phase and parameter sweeps, attached mass checks and browser regression. These checks describe simulator behaviour, not diagnostic performance.