Intensive Care
Clinical physiology teaching

Heart Sound Lab

Explore murmurs through sound, timing and cardiac anatomy

Heart Sound Lab

About this simulator

Developed by Alex Psirides using an advanced AI model. Trained on public access datasets. See below for sources.

v1.21.1 · Runs offline
Adult recordings · phase-evolving sound synthesis

The current experimental sound models remain available alongside the v1.17 recording-derived default. This release reorganises About and Advanced; it does not change the acoustic synthesis or clinical validation status.

Version 1.21.1. Heart Sound Lab is a research-informed cardiac auscultation teaching prototype, not a clinically validated simulator. It combines synthesised heart sounds and physiological timing with processed, reference-derived murmur textures and synthetic turbulence. The output is illustrative, not a verified recreation of any individual patient or a clinically validated representation of the selected diagnosis.

Version history

Most recent first. Select a release to see its changes.

v1.21.1 · Information organisation and source separation

Reorganised About and Advanced in descending release order. Grouped all reference archives at the bottom, while preserving acoustic engines, data banks and assessment controls.

v1.21 · Time-varying learned source–filter synthesis

Fitted three autoregressive acoustic states per sound class, with gradual evolution during S1, S2 and murmurs. This remains an experimental synthetic generator, not a perceptually validated replacement for the recording-derived default.

Detailed methods and limitations

The new fully generative option learns three overlapping acoustic states within each source event or grain. Three stable AR(12) filters share new seeded noise excitation, and their outputs are smoothly weighted through the simulated event. It retains the clinically programmed murmur envelope, site and stethoscope transmission. Source WAV samples and Fourier phases are never accessed in the new rendering path. The reference snippets are not clinically reviewed at the sample-boundary level, and the adult TR/AR murmur data have only one contributing participant each. The mode is experimental; v1.17 recording-derived synthesis remains the default pending blinded listening tests.

v1.20 · Learned autoregressive source–filter synthesis

Introduced a regularised learned filter with seeded excitation instead of source-waveform replay. Held-out whole-cycle spectral comparisons improved for some diagnoses, but did not establish audible realism.

Detailed methods and limitations

New 12th-order stable autoregressive filters fitted to adult S1/S2 segments and auscultation-positive MR/TR/AR fragments, supplemented by CirCor murmur-quality textures where adult coverage is lacking. Every output sample is generated from new deterministic stochastic excitation and fitted scalar coefficients; no original waveform segments or individual Fourier phases are replayed. S1/S2 markers were algorithmically selected and are not clinically reviewed. The adult TR and AR training groups contain only one participant each. The v1.17 recording-derived engine remains the default pending blinded clinician listening validation.

v1.19 · Time–frequency atlas and reconstruction experiments

Analysed diagnosis-separated BUET recordings with patient-level holdouts. Explored true synthesis using a 16-band × 32-phase atlas and separately studied magnitude-spectrogram reconstruction, which is not an independently generative result.

Detailed methods and limitations

The experimental statistical-atlas engine uses measurements from 46 BUET BMD-HS training patients with a single listed diagnosis (92 recording selections, 88 meeting the confidence threshold), and excludes 12 held-out patients from those fits. The 4 kHz recordings were analysed at 16 log-spaced frequency bands and folded into 32 proposed cardiac-phase bins using autocorrelation. The filtered parameters change seeded noise-driven synthesis, rather than replaying any of the original WAV samples.

Limitations: BUET provides patient-level valve labels, not manually confirmed murmur onset, audible severity or S1/S2 event labels. The phase estimates are heuristic, the recordings are heavily weighted towards low frequencies, and whole-cycle spectral distance alone does not establish clinical or perceptual realism. The v1.19 synthetic option is not established as superior to v1.18 or the recording-derived v1.17 mode.

An additional offline study reconstructed two Fraiwan adult excerpts from their detailed magnitude spectrograms using iterative phase estimation. That is source-conditioned signal reconstruction, not the generation of an independent patient from diagnostic information; it is not embedded as a general synthesiser.

v1.18 · Procedural, parameter-only synthesis

Fitted S1/S2 temporal envelopes, acoustic band energies and turbulence characteristics without replaying source PCM. Kept v1.17 as the default following mixed spectral results.

v1.17 · Recording-informed resynthesis

Added natural-event reconstruction informed by short adult S1/S2 and murmur fragments, alongside a separate fully synthetic comparator. Original recordings remain available for listening; event boundaries require independent review.

v1.16 · Acoustic-event and anatomical transmission refinements

Added independently seeded valve-sound excitation, non-stationary murmur colour and turbulence, and separate bell/diaphragm response profiles. Four-site BUET comparisons inform only small, bounded frequency adjustments; the other listening positions use explicitly approximate anatomical contours. These signals have not been validated as indistinguishable from clinical recordings.

The previous v1.15 hybrid remains available for immediate A/B comparison. The 18 teaching cases, reference recordings and assessment are retained.

v1.15 · Interactive cardiac-cycle teaching and Self-test

Added the cardiac-cycle scrubber, short previews, baseline/manoeuvre comparison, arc physiology controls, waveform/audio toggles and a separate Self-test view. Interface revisions subsequently corrected control geometry, spacing and labels.

v1.14 · Stethoscope and anatomical listening models

Added site-dependent frequency filtering, distinct bell/diaphragm response and playback checks. These are measured-direction teaching approximations, not calibrated stethoscope transfer functions.

v1.13 · Transient and murmur-texture improvements

Revised S1/S2, clicks and additional heart sounds, with less repetitive turbulence and reviewable murmur-only acoustic measurements.

v1.12–v1.10 · Segmentation and phase-resolved physiological synthesis

Introduced offline S1/S2 proposal analysis, exportable marker review, a phase-resolved physiological engine, site-dependent filtering and revised manoeuvre responses. Automatic boundaries are heuristic suggestions, not verified annotations.

The Advanced workspace was expanded so segmentation, reference audio and research validation tools remained separate from the simplified teaching interface.

v1.9 · BUET adult valve recording integration

Added unchanged BUET BMD-HS recordings for reference listening and conservative source-informed AS/MS low-frequency calibration; retained dataset attribution and restrictions.

v1.8 · Adult regurgitation dataset integration

Added Fraiwan/Ibnian/Haider adult clinical recordings, alongside separate adult-informed MR/TR synthesis and provisional AR modelling.

v1.7 · Dynamic turbulence and adult reference workspace

The v1.7 generator synthesises band-limited, partly correlated, time-varying stochastic turbulence with independent microstructure, small beat-to-beat changes and illustrative listening-site attenuation. It does not solve turbulent flow numerically and is not fitted to confirmed adult valvular recordings as delivered.

The adult recording workspace analyses an explicitly user-selected murmur-only interval using windowed FFT band-power estimates. There is no automatic murmur segmentation, no automated diagnosis and no severity prediction.

v1.6 · Spectral source calibration

14 embedded source-texture banks (7 from CirCor and 7 from the 2016 Challenge) were analysed using Welch spectral power estimates. Twelve overlapping bands between 25 and 1800 Hz were fitted using non-negative least-squares to the recorded acoustic-quality spectra. The new pure-synthetic engine excites each band with independent, seeded turbulence; the v1.6 hybrid adds a quiet (~21% uncorrected linear mix) source waveform component.

Validation boundary: fitting a synthetic output to a source spectrum checks frequency distribution, not clinical diagnostic similarity. Event timing and envelope are checked against standard clinical descriptions, but the model has not been prospectively validated against a blinded, echocardiographically confirmed adult patient cohort, nor assessed for listener accuracy.

v1.5 · Adaptive synthesis and formative assessment

Adaptive synthesis: short source-derived acoustic fragments are grain-crossfaded and blended with separately filtered turbulent excitation. Ejection murmurs have a changing spectral character during systole; successive beats vary modestly. This is a modelled demonstration, not an empirical reproduction of adult pathology.

Physiology: a synchronised four-valve schematic shows ventricular filling, ejection and possible regurgitant flow. Preload and afterload controls change illustrative sound amplitude; anatomical motion, flow direction and manoeuvre response are not quantitatively validated.

Assessment: ten unlabelled listening exercises use programmed teaching categories, distractors, reveal annotations and explanatory feedback. Scores are formative only.

v1.4 and earlier · Early development builds

Detailed release-by-release notes for these earliest prototypes are not contained in the current About history; no changes are being inferred.

Model methods, validation limits and analytics

How the sounds are generated

  • Synthesised elements: S1 and S2, cardiac-cycle timing, respiratory changes in S2, the murmur intensity envelopes, retiming with heart rate, and the illustrative effects of auscultation site and bedside manoeuvres are generated by the simulator. They represent teaching models, not measured haemodynamics in individual patients.
  • Reference-derived elements: The CirCor and PhysioNet modes process short acoustic textures from published phonocardiogram recordings and combine these with synthetic timing and volume envelopes. They are not unaltered, diagnosis-confirmed patient recordings. The separate reference-audio player presents original excerpts for comparison.
  • Clinical source labels: The original publication for the adult AUTHHSDB / PhysioNet 2016 collection C describes patients with aortic stenosis or mitral regurgitation whose valve disease was assessed by echocardiography. These supplementary diagnoses are separate from the Challenge’s principal normal/abnormal labels. Their existence does not verify that a particular embedded AS or MR texture maps correctly to a particular source recording. That record-by-record provenance audit is outstanding.
  • Other lesions: Many CirCor recordings are paediatric and are labelled by murmur timing or acoustic quality rather than a confirmed adult valve lesion. Presets such as mitral stenosis, aortic regurgitation, HCM and PDA use illustrative, sometimes acoustic-quality-derived material; their names must not be read as validated diagnoses of the contributing sound recordings.

Validation status

Research-informed educational prototype; not clinically validated. Earlier releases underwent engineering and limited spectral comparisons; v1.5 adds unvalidated acoustic modelling and teaching/assessment functions. Those analyses indicate signal properties and model behaviour but do not establish diagnostic fidelity, listener recognition, lesion-specific realism or educational effectiveness.

No independent blinded assessment by clinicians, comprehensive lesion-specific validation against independently sourced adult recordings, or prospective teaching-outcome study has been completed. Assessment scores reflect recognition of the programmed teaching cases only. The source-to-embedded-texture provenance mapping is also not yet independently reproducible. The model must not be used to diagnose patients, guide treatment or assess clinical competence.

  • Four independent research datasets were used: CirCor DigiScope, PhysioNet / Computing in Cardiology Challenge 2016, the Fraiwan / Ibnian / Haider adult regurgitation dataset, and the BUET Multi-disease Heart Sound Dataset. The other supplied ZIP files contain a selected CirCor extract and a PhysioNet annotation supplement. Filenames and source links appear above.
  • Published recordings and annotations remain attributable to their authors and PhysioNet. Consult the original dataset pages for licence terms, citation requirements and permitted redistribution.
  • Some sound textures are embedded as Base64 data for offline playback. The v1.5 source-bank manifest provides class-level contributing IDs and SHA-256 checksums of embedded PCM banks. This improves inspectability but does not establish independently verified source-to-grain mapping, original WAV checksums or lesion confirmation. Claims about the provenance of individual rendered murmurs remain provisional.

Analytics: When deployed to a server that provides /beta-analytics.js, that script loads in the page head and can collect usage information according to the site's configuration. The script is not included in this standalone file and cannot function without the server resource. The simulator's audio generation itself runs locally in your browser.

References and source archives

Original datasets, archive inventory, publications, licences and further clinical reading. These sources are separate from the application release history.

1. CirCor DigiScope phonocardiogram dataset, v1.0.3 (2022)

Uploaded archive: the-circor-digiscope-phonocardiogram-dataset-1.0.3.zip

Clinical phonocardiogram recordings with auscultation-site, S1/S2 segmentation and descriptive murmur annotations. Used to study spectral texture, timing and sound-quality categories and to create the CirCor-based v1.2 engine.

Dataset: Oliveira J, Renna F, Costa P, et al. The CirCor DigiScope Phonocardiogram Dataset (v1.0.3), PhysioNet (2022). doi:10.13026/tshs-mw03. Official archive.

Related paper: Oliveira JH et al. The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. IEEE JBHI (2021). doi:10.1109/JBHI.2021.3137048.

2. Selected CirCor reference recordings

Uploaded archive: To Upload.zip

Selected recordings and metadata for CirCor subjects 49628, 49754 and 50159, including WAV, TSV, HEA and subject-description files. Used for closer listening and analysis of harsh, blowing and other systolic murmur qualities.

Original source: The same CirCor DigiScope v1.0.3 dataset above. This is a selected subset, not a separate clinical study or independent dataset.

3. PhysioNet / Computing in Cardiology Challenge 2016, v1.0.0

Uploaded archive: PhysioNet 2016 heart-sound training archive.zip

Multi-source heart-sound recordings supplied for acoustic analysis and phase-derived sound textures. The main Challenge labels are normal/abnormal. Supplementary collection C metadata identify a small adult aortic stenosis (AS) and mitral regurgitation (MR) cohort, as described in the original AUTHHSDB publication. The identity and diagnosis of every embedded texture have not been independently traced and verified against its original recording.

Official source: Liu C, Springer D, Moody B, et al. Classification of Heart Sound Recordings: The PhysioNet/Computing in Cardiology Challenge 2016 (v1.0.0). Official dataset and download.

Reference publication: Liu C et al. An open access database for the evaluation of heart sound algorithms. Physiological Measurement 37:2181–2213 (2016). doi:10.1088/0967-3334/37/12/2181.

4. PhysioNet 2016 cardiac-cycle annotations and supplemental labels

Uploaded archive: annotations.zip

Springer-method cardiac-cycle segmentation, corrected S1/systole/S2/diastole boundaries and supplementary metadata. Used to select phase-specific acoustic material. The appendix contains additional lesion and murmur labels for certain recordings; annotation availability and diagnostic certainty differ by collection. The simulator’s embedded sample-to-record mapping remains to be independently audited.

Original source: The PhysioNet Challenge 2016 dataset, with annotations.zip. This is an annotation supplement to archive 3, not an independent recording collection.

5. Fraiwan / Ibnian / Haider adult regurgitation dataset (2025)

Uploaded archive: A Dataset of Heart Sound Regurgitation of Patients.zip

The user-provided archive contains 400 4 kHz mono WAV files from 104 participants, including one metallic-prosthesis file in addition to 399 files in the four published clinical categories. The attached annotation spreadsheet provides echocardiographic findings and grade by auscultation site. Eleven participants have normal echo annotations at all four sites. Grade-0/trace regurgitation was excluded from positive-class fitting. Two or more held-out patients are excluded from the embedded training data for each group.

Dataset, DOI 10.17632/jfbdvjw6sf.1 (CC BY 4.0 on the repository). Published report: Fraiwan M, Ibnian A, Haider NS, Data in Brief 63 (2025) 112081, DOI 10.1016/j.dib.2025.112081.

Use in simulator: Selected 8-second original excerpts and high-pass/energy-selected texture grains are embedded with attribution. Source material comes from the Littmann 3200, which applies instrumental filtering. The dataset provides no murmur-only segmentation and the recorded amplitude is not comparable across patients; the model therefore applies only bounded spectral adjustment for MR and TR. AR grade 1 only. None of this establishes that a given recording contains an audible murmur, or that the synthesis is diagnostically validated.

6. BUET Multi-disease Heart Sound Dataset (2024; published 2026)

Uploaded archive: BMD-HS-Dataset-main.zip

Required attribution: BUET Multi-disease Heart Sound Dataset © 2024 mHealth Lab. Authors: Ali SN, Zahin A, Shuvo SB, et al. BUET multi-disease heart sound dataset: A comprehensive auscultation dataset for developing computer-aided diagnostic systems. Computer Methods and Programs in Biomedicine Update 9 (2026), 100237. doi:10.1016/j.cmpbup.2026.100237.

Source and licence: GitHub repository · CC BY-NC-ND 4.0 (attribution, non-commercial, no sharing adapted recordings). Original full-duration WAV reference recordings are included without changing their bytes for non-commercial teaching. Separate synthetic low-frequency parameters were measured statistically from single-diagnosis training patients; no raw BUET waveform is used in the murmur synthesiser.

Verified archive inventory: 872 WAVs at 4 kHz, 109 subject IDs, eight recordings per subject. Two files are shorter than the nominal 20 seconds. The published article reports 864 recordings, and the repository README contains an inconsistent patient count; this application reports counts verified from the uploaded archive. Disease labels indicate patient diagnosis, not confirmed murmur presence in each recording. This source has no murmur-only interval annotation.

Use restrictions: The embedded originals retain the mHealth Lab licence. Don't redistribute modified versions or use these recordings commercially without appropriate permission. The application is an educational research prototype, not a clinically validated diagnostic model.

Heart Sound Lab · assessment

Self-test

Listen to an unidentified cardiac sound and choose its likely diagnosis. The test uses the same synthesised waveform as Exploration, without the anatomical teaching panels.

Stopped

Self-test

Hide the diagnosis and identify the murmur by timing, character and site.

Ten-case listening assessment

Unlabelled clinical teaching scenarios, normal variants and deliberately similar sounds. The grade reflects the selected programmed pattern, not clinical competence.

Educational assessment of programmed examples, not a clinical competence examination. All reference datasets retain their source attribution in About.

Current teaching case

Normal S1 and S2

Physiology · no murmur
Best heard: Apex

75%
Audio uses an adjustable murmur model informed by recorded acoustic-quality spectra, with illustrative attenuation at the mitral area. Headphones are recommended.

Cardiac cycle

Inspect cardiac cycleLive · 0.00 s

Drag or step through the same timeline that drives the ECG, phonocardiogram and valve display. Hear moment plays a short excerpt at the selected position.

The lower trace is derived from the actual synthesised sound. The pink envelope shows the murmur contribution. S1 starts ventricular systole; S2 begins diastole. Vertical cursor follows playback, including half-speed mode.

Valve and flow teaching model

Synchronised with cardiac cycle

Illustrative valve movement

Animated schematic, not an anatomical or haemodynamic reconstruction
RIGHT HEARTLEFT HEART RIGHT ATRIUMRIGHT VENTRICLELEFT ATRIUMLEFT VENTRICLE PAAo TRICUSPIDMITRAL PA
S1 · atrioventricular valve closure0.00 s of 0.83 s

At S1 the atrioventricular valves close. Ejection follows as the semilunar valves open.

Where the sound is heard

Patient’s rightLeft
Anterior chest, facing the patient. Auscultation points mark sound transmission, not the valves’ exact anatomical positions. Select a point to compare sounds.

Anatomical origin

Normal valve closure
PAAoRARVLALV
Simplified flow schematic, not anatomical scale. RA/RV: right heart; LA/LV: left heart; PA: pulmonary artery; Ao: aorta. The outflow arrows connect the ventricles to their arteries.

Why this sound occurs

Timing
Quality
Heard best
Radiation

Haemodynamic mechanism

Bedside examination